Impiego della gas cromatografia a ionizzazione di fiamma (GC-FID) per la misura dei solventi tal quali nelle urine.

Translated title of the contribution: Use of gas chromatography with flame ionization (GC-FID) in the measurement of solvents in the urine

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The urinary concentration of some solvents (acetone, cyclohexane, 1,2 dichloropropane, n-hexane, methyl ethyl ketone, perchloroethylene, styrene, toluene, 1,1,1, trichloroethane) was measured by means of a gas chromatography Hewlett-Packard 5890 supplied with a flame ionization detector (GC-FID, DANI HS 3950). The coefficient of variation of the method was lower than 5%. The sensitivity of the GC-FID was very similar to what of mass spectrometer detector (GC-MSD, HP 5970 A).

Original languageItalian
Pages (from-to)21-24
Number of pages4
JournalGiornale Italiano di Medicina del Lavoro
Volume9
Issue number1
Publication statusPublished - Jan 1987

Fingerprint

Tetrachloroethylene
Flame Ionization
Styrene
Toluene
Acetone
Gas Chromatography
Urine
Cyclohexane
1,1,1-trichloroethane
propylene dichloride
methylethyl ketone
n-hexane

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health
  • Medicine(all)

Cite this

@article{8562b7ed522d40208b33f362147a4c27,
title = "Impiego della gas cromatografia a ionizzazione di fiamma (GC-FID) per la misura dei solventi tal quali nelle urine.",
abstract = "The urinary concentration of some solvents (acetone, cyclohexane, 1,2 dichloropropane, n-hexane, methyl ethyl ketone, perchloroethylene, styrene, toluene, 1,1,1, trichloroethane) was measured by means of a gas chromatography Hewlett-Packard 5890 supplied with a flame ionization detector (GC-FID, DANI HS 3950). The coefficient of variation of the method was lower than 5{\%}. The sensitivity of the GC-FID was very similar to what of mass spectrometer detector (GC-MSD, HP 5970 A).",
author = "S. Ghittori and Fiorentino, {M. L.} and M. Imbriani",
year = "1987",
month = "1",
language = "Italian",
volume = "9",
pages = "21--24",
journal = "Giornale Italiano di Medicina del Lavoro",
issn = "0391-9889",
publisher = "Giardini Editori e Stampatori",
number = "1",

}

TY - JOUR

T1 - Impiego della gas cromatografia a ionizzazione di fiamma (GC-FID) per la misura dei solventi tal quali nelle urine.

AU - Ghittori, S.

AU - Fiorentino, M. L.

AU - Imbriani, M.

PY - 1987/1

Y1 - 1987/1

N2 - The urinary concentration of some solvents (acetone, cyclohexane, 1,2 dichloropropane, n-hexane, methyl ethyl ketone, perchloroethylene, styrene, toluene, 1,1,1, trichloroethane) was measured by means of a gas chromatography Hewlett-Packard 5890 supplied with a flame ionization detector (GC-FID, DANI HS 3950). The coefficient of variation of the method was lower than 5%. The sensitivity of the GC-FID was very similar to what of mass spectrometer detector (GC-MSD, HP 5970 A).

AB - The urinary concentration of some solvents (acetone, cyclohexane, 1,2 dichloropropane, n-hexane, methyl ethyl ketone, perchloroethylene, styrene, toluene, 1,1,1, trichloroethane) was measured by means of a gas chromatography Hewlett-Packard 5890 supplied with a flame ionization detector (GC-FID, DANI HS 3950). The coefficient of variation of the method was lower than 5%. The sensitivity of the GC-FID was very similar to what of mass spectrometer detector (GC-MSD, HP 5970 A).

UR - http://www.scopus.com/inward/record.url?scp=0023166365&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023166365&partnerID=8YFLogxK

M3 - Articolo

VL - 9

SP - 21

EP - 24

JO - Giornale Italiano di Medicina del Lavoro

JF - Giornale Italiano di Medicina del Lavoro

SN - 0391-9889

IS - 1

ER -