LE VARIAZIONI DELL'IMPEDENZA ELETTRICA TRANSTORACICA NELLA VALUTAZIONE EMODINAMICA DEI PAZIENTI OPERATI A CUORE APERTO

Translated title of the contribution: Variations of transthoracic electrical impedance for hemodynamic evaluation of patients after open heart surgery

R. Alfieri, O. Alfieri

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Adequate assessment of cardiac function in patients who have undergone open intracardiac operations requires determination of cardiac output. Electric impedance technique of determining cardiac output in intensive care unit is presented. Routine measurement of cardiac output in the immediate postoperative period has allowed important innovations in the care of the patients: preclinical diagnosis of low cardiac output and prophylactic treatment; artificial pacing at optimal rate; and accurate assessment of the effectiveness of the treatment measures.

Original languageItalian
Title of host publicationATENEO PARMENSE
Pages267-273
Number of pages7
Volume46
Edition4
Publication statusPublished - 1975

Fingerprint

Impedance Cardiography
Electric Impedance
Cardiac Output
Thoracic Surgery
Hemodynamics
Low Cardiac Output
Postoperative Period
Intensive Care Units
Patient Care
Therapeutics

ASJC Scopus subject areas

  • Medicine(all)

Cite this

LE VARIAZIONI DELL'IMPEDENZA ELETTRICA TRANSTORACICA NELLA VALUTAZIONE EMODINAMICA DEI PAZIENTI OPERATI A CUORE APERTO. / Alfieri, R.; Alfieri, O.

ATENEO PARMENSE. Vol. 46 4. ed. 1975. p. 267-273.

Research output: Chapter in Book/Report/Conference proceedingChapter

@inbook{3414f7a846904310bfe7b2f037ac57af,
title = "LE VARIAZIONI DELL'IMPEDENZA ELETTRICA TRANSTORACICA NELLA VALUTAZIONE EMODINAMICA DEI PAZIENTI OPERATI A CUORE APERTO",
abstract = "Adequate assessment of cardiac function in patients who have undergone open intracardiac operations requires determination of cardiac output. Electric impedance technique of determining cardiac output in intensive care unit is presented. Routine measurement of cardiac output in the immediate postoperative period has allowed important innovations in the care of the patients: preclinical diagnosis of low cardiac output and prophylactic treatment; artificial pacing at optimal rate; and accurate assessment of the effectiveness of the treatment measures.",
author = "R. Alfieri and O. Alfieri",
year = "1975",
language = "Italian",
volume = "46",
pages = "267--273",
booktitle = "ATENEO PARMENSE",
edition = "4",

}

TY - CHAP

T1 - LE VARIAZIONI DELL'IMPEDENZA ELETTRICA TRANSTORACICA NELLA VALUTAZIONE EMODINAMICA DEI PAZIENTI OPERATI A CUORE APERTO

AU - Alfieri, R.

AU - Alfieri, O.

PY - 1975

Y1 - 1975

N2 - Adequate assessment of cardiac function in patients who have undergone open intracardiac operations requires determination of cardiac output. Electric impedance technique of determining cardiac output in intensive care unit is presented. Routine measurement of cardiac output in the immediate postoperative period has allowed important innovations in the care of the patients: preclinical diagnosis of low cardiac output and prophylactic treatment; artificial pacing at optimal rate; and accurate assessment of the effectiveness of the treatment measures.

AB - Adequate assessment of cardiac function in patients who have undergone open intracardiac operations requires determination of cardiac output. Electric impedance technique of determining cardiac output in intensive care unit is presented. Routine measurement of cardiac output in the immediate postoperative period has allowed important innovations in the care of the patients: preclinical diagnosis of low cardiac output and prophylactic treatment; artificial pacing at optimal rate; and accurate assessment of the effectiveness of the treatment measures.

UR - http://www.scopus.com/inward/record.url?scp=0016786801&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0016786801&partnerID=8YFLogxK

M3 - Capitolo

C2 - 1212275

AN - SCOPUS:0016786801

VL - 46

SP - 267

EP - 273

BT - ATENEO PARMENSE