Variations of tumor control and rectum complication probabilities due to random set-up errors during conformal radiation therapy of prostate cancer

Gabriela Ragazzi, Paola Mangili, Claudio Fiorino, Giovanni Mauro Cattaneo, Angelo Bolognesi, Michele Reni, Riccardo Calandrino

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

Background and purpose: The effect of random set-up errors on tumor control probability (TCP) and rectum complication probability (NTCP) on 3D conformal treatment planning of prostate cancer has been investigated by applying the convolution method originally proposed by Leong (Leong, J. Implementation of random positioning error in computerized radiation treatment planning systems as a result of fractionation. Phys. Med. Biol. 32: 327-334, 1987). Materials and methods: The combined influence of the standard deviation of the random shifts probability distribution (σ) of the dose and of the Beam's-eye-view margin (M) between the clinical target volume (CTV) and the edge of the blocks have been investigated in two patients. Results and conclusions: Random set-up error has been found to decrease TCP (for a typical 70 Gy CTV mean dose) by up to 6% for a 1 cm margin (σ = 7 mm). When M is equal to or larger than 1.5 cm, no relevant effects on TCP are obtained. Maximum acceptable TCP values (corresponding to a rectum NTCP equal to 5%) have been derived and the dependence on σ and M has been investigated.

Original languageEnglish
Pages (from-to)259-263
Number of pages5
JournalRadiotherapy and Oncology
Volume44
Issue number3
DOIs
Publication statusPublished - Sep 1997

Fingerprint

Rectum
Prostatic Neoplasms
Radiotherapy
Neoplasms
Radiation
Therapeutics

Keywords

  • Biological models
  • Conformal radiotherapy
  • Margins in radiotherapy
  • Optimization in radiotherapy
  • Positioning errors

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging
  • Urology

Cite this

Variations of tumor control and rectum complication probabilities due to random set-up errors during conformal radiation therapy of prostate cancer. / Ragazzi, Gabriela; Mangili, Paola; Fiorino, Claudio; Cattaneo, Giovanni Mauro; Bolognesi, Angelo; Reni, Michele; Calandrino, Riccardo.

In: Radiotherapy and Oncology, Vol. 44, No. 3, 09.1997, p. 259-263.

Research output: Contribution to journalArticle

@article{e9707466132348fc9b959b64bd51f0bc,
title = "Variations of tumor control and rectum complication probabilities due to random set-up errors during conformal radiation therapy of prostate cancer",
abstract = "Background and purpose: The effect of random set-up errors on tumor control probability (TCP) and rectum complication probability (NTCP) on 3D conformal treatment planning of prostate cancer has been investigated by applying the convolution method originally proposed by Leong (Leong, J. Implementation of random positioning error in computerized radiation treatment planning systems as a result of fractionation. Phys. Med. Biol. 32: 327-334, 1987). Materials and methods: The combined influence of the standard deviation of the random shifts probability distribution (σ) of the dose and of the Beam's-eye-view margin (M) between the clinical target volume (CTV) and the edge of the blocks have been investigated in two patients. Results and conclusions: Random set-up error has been found to decrease TCP (for a typical 70 Gy CTV mean dose) by up to 6{\%} for a 1 cm margin (σ = 7 mm). When M is equal to or larger than 1.5 cm, no relevant effects on TCP are obtained. Maximum acceptable TCP values (corresponding to a rectum NTCP equal to 5{\%}) have been derived and the dependence on σ and M has been investigated.",
keywords = "Biological models, Conformal radiotherapy, Margins in radiotherapy, Optimization in radiotherapy, Positioning errors",
author = "Gabriela Ragazzi and Paola Mangili and Claudio Fiorino and Cattaneo, {Giovanni Mauro} and Angelo Bolognesi and Michele Reni and Riccardo Calandrino",
year = "1997",
month = "9",
doi = "10.1016/S0167-8140(97)00096-0",
language = "English",
volume = "44",
pages = "259--263",
journal = "Radiotherapy and Oncology",
issn = "0167-8140",
publisher = "Elsevier Ireland Ltd",
number = "3",

}

TY - JOUR

T1 - Variations of tumor control and rectum complication probabilities due to random set-up errors during conformal radiation therapy of prostate cancer

AU - Ragazzi, Gabriela

AU - Mangili, Paola

AU - Fiorino, Claudio

AU - Cattaneo, Giovanni Mauro

AU - Bolognesi, Angelo

AU - Reni, Michele

AU - Calandrino, Riccardo

PY - 1997/9

Y1 - 1997/9

N2 - Background and purpose: The effect of random set-up errors on tumor control probability (TCP) and rectum complication probability (NTCP) on 3D conformal treatment planning of prostate cancer has been investigated by applying the convolution method originally proposed by Leong (Leong, J. Implementation of random positioning error in computerized radiation treatment planning systems as a result of fractionation. Phys. Med. Biol. 32: 327-334, 1987). Materials and methods: The combined influence of the standard deviation of the random shifts probability distribution (σ) of the dose and of the Beam's-eye-view margin (M) between the clinical target volume (CTV) and the edge of the blocks have been investigated in two patients. Results and conclusions: Random set-up error has been found to decrease TCP (for a typical 70 Gy CTV mean dose) by up to 6% for a 1 cm margin (σ = 7 mm). When M is equal to or larger than 1.5 cm, no relevant effects on TCP are obtained. Maximum acceptable TCP values (corresponding to a rectum NTCP equal to 5%) have been derived and the dependence on σ and M has been investigated.

AB - Background and purpose: The effect of random set-up errors on tumor control probability (TCP) and rectum complication probability (NTCP) on 3D conformal treatment planning of prostate cancer has been investigated by applying the convolution method originally proposed by Leong (Leong, J. Implementation of random positioning error in computerized radiation treatment planning systems as a result of fractionation. Phys. Med. Biol. 32: 327-334, 1987). Materials and methods: The combined influence of the standard deviation of the random shifts probability distribution (σ) of the dose and of the Beam's-eye-view margin (M) between the clinical target volume (CTV) and the edge of the blocks have been investigated in two patients. Results and conclusions: Random set-up error has been found to decrease TCP (for a typical 70 Gy CTV mean dose) by up to 6% for a 1 cm margin (σ = 7 mm). When M is equal to or larger than 1.5 cm, no relevant effects on TCP are obtained. Maximum acceptable TCP values (corresponding to a rectum NTCP equal to 5%) have been derived and the dependence on σ and M has been investigated.

KW - Biological models

KW - Conformal radiotherapy

KW - Margins in radiotherapy

KW - Optimization in radiotherapy

KW - Positioning errors

UR - http://www.scopus.com/inward/record.url?scp=0030859445&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030859445&partnerID=8YFLogxK

U2 - 10.1016/S0167-8140(97)00096-0

DO - 10.1016/S0167-8140(97)00096-0

M3 - Article

C2 - 9380825

AN - SCOPUS:0030859445

VL - 44

SP - 259

EP - 263

JO - Radiotherapy and Oncology

JF - Radiotherapy and Oncology

SN - 0167-8140

IS - 3

ER -